UK Power Networks Open Data Portal
OpenDataSoft Data Hub source domain for UK Power Networks Open Data Portal, exposing datasets and records through the OpenDataSoft Explore API v2.1.
Public data
About this public data
UK Power Networks Open Data Portal is a public data source published by UK Power Networks Open Data Portal for ukpowernetworks, United Kingdom. It is listed in Open data sources and made available under OGL, with the latest catalogue update recorded on May 18, 2026.
This catalogue entry connects 128 public source references, preview assets, or live views so teams can evaluate the data before adding it to a workspace.
- Provider:UK Power Networks Open Data Portal
- Category:Open data sources
- Geography:ukpowernetworks, United Kingdom
- Sources:128
132kV Circuit Operational Data Half Hourly
UpdatedOct 19, 2026Introduction UK Power Network maintains the 132kV voltage level network and below. An important part of the distribution network is distributing this electricity across our regions through circuits. Electricity enters our network through Super Grid Transformers at substations shared with National Grid we call Grid Supply Points. It is then sent at across our 132 kV Circuits towards our grid substations and primary substations. These circuits can be viewed on the single line diagrams in our Long-Term Development Statements (LTDS) and the underlying data is then found in the LTDS tables. This dataset provides half-hourly current and power flow data across these named circuits from 2021 through to the previous month across our license areas. The data are aligned with the same naming convention as the LTDS for improved interoperability. Care is taken to protect the private affairs of companies connected to the 132 kV network, resulting in the redaction of certain circuits. Where redacted, we provide monthly statistics to continue to add value where possible. Where monthly statistics exist but half-hourly is absent, this data has been redacted. To find which circuit you are looking for, use the ‘ltds_line_name’ that can be cross-referenced in the 132kV Circuits Monthly Data, which describes by month what circuits were triaged, if they could be made public, and what the monthly statistics are of that site. If you want to download all this data, it is perhaps more convenient from our public sharepoint: Sharepoint This dataset is part of a larger endeavour to share more operational data on UK Power Networks assets. Please visit our Network Operational Data Dashboard for more operational datasets. Methodological Approach The dataset is not derived, it is the measurements from our network stored in our historian. The measurement devices are taken from current transformers attached to the cable at the circuit breaker, and power is derived combining this with the data from voltage transformers physically attached to the busbar. The historian stores datasets based on a report-by-exception process, such that a certain deviation from the present value must be reached before logging a point measurement to the historian. We extract the data following a 30-min time weighted averaging method to get half-hourly values. Where there are no measurements logged in the period, the data provided is blank; due to the report-by-exception process, it may be appropriate to forward fill this data for shorter gaps. We developed a data redactions process to protect the privacy of companies according to the Utilities Act 2000 section 105.1.b, which requires UK Power Networks to not disclose information relating to the affairs of a business. For this reason, where the demand of a private customer is derivable from our data and that data is not already public information (e.g., data provided via Elexon on the Balancing Mechanism), we redact the half-hourly time series, and provide only the monthly averages. This redaction process considers the correlation of all the data, of only corresponding periods where the customer is active, the first order difference of all the data, and the first order difference of only corresponding periods where the customer is active. Should any of these four tests have a high linear correlation, the data is deemed redacted. This process is not simply applied to only the circuit of the customer, but of the surrounding circuits that would also reveal the signal of that customer. The directionality of the data is not consistent within this dataset. Where directionality was ascertainable, we arrange the power data in the direction of the LTDS "from node" to the LTDS "to node". Measurements of current do not indicate directionality and are instead positive regardless of direction. In some circumstances, the polarity can be negative, and depends on the data commissioner's decision on what the operators in the control room might find most helpful in ensuring reliable and secure network operation. Quality Control Statement The data is provided "as is". In the design and delivery process adopted by the DSO, customer feedback and guidance is considered at each phase of the project. One of the earliest steers was that raw data was preferable. This means that we do not perform prior quality control screening to our raw network data. The result of this decision is that network rearrangements and other periods of non-intact running of the network are present throughout the dataset, which has the potential to misconstrue the true utilisation of the network, which is determined regulatorily by considering only by in-tact running arrangements. Therefore, taking the maximum or minimum of these measurements are not a reliable method of correctly ascertaining the true utilisation. This does have the intended added benefit of giving a realistic view of how the network was operated. The critical feedback was that our customers have a desire to understand what would have been the impact to them under real operational conditions. As such, this dataset offers unique insight into that. Assurance Statement Creating this dataset involved a lot of human data imputation. At UK Power Networks, we have differing software to run the network operationally (ADMS) and to plan and study the network (PowerFactory). The measurement devices are intended to primarily inform the network operators of the real time condition of the network, and importantly, the network drawings visible in the LTDS are a planning approach, which differs to the operational. To compile this dataset, we made the union between the two modes of operating manually. A team of data scientists, data engineers, and power system engineers manually identified the LTDS circuit from the single line diagram, identified the line name from LTDS Table 2a/b, then identified the same circuit in ADMS to identify the measurement data tags. This was then manually inputted to a spreadsheet. Any influential customers to that circuit were noted using ADMS and the single line diagrams. From there, a python code is used to perform the triage and compilation of the datasets. There is potential for human error during the manual data processing. These issues can include missing circuits, incorrectly labelled circuits, incorrectly identified measurement data tags, incorrectly interpreted directionality. Whilst care has been taken to minimise the risk of these issues, they may persist in the provided dataset. Any uncertain behaviour observed by using this data should be reported to allow us to correct as fast as possible. Additional Information Definitions of key terms related to this dataset can be found in the Open Data Portal Glossary. Download dataset information: Metadata (JSON) To view this data please register and login.
OpenDataSoft datasetcompatibleUK Power Networks Licence Area 132kV Underground Cables
UpdatedMar 31, 2026Introduction Shapefile showing UK Power Networks' 132kV underground cables. Methodological Approach Data Extraction: Shapefiles are extracted from our geospatial mapping system - NetMap. Vectorisation: Shapefiles will be regularly updated to account for vectorisation updates. Quality Control Statement The data is provided "as is". Please be aware that not all locations are fully vectorised yet, so the dataset provides only partial coverage. Refer to our LPN Vectorisation Delivery dataset. Assurance Statement The Open Data Team checked to ensure data accuracy and consistency. Other Download dataset information: Metadata (JSON) Definitions of key terms related to this dataset can be found in the Open Data Portal Glossary: https://ukpowernetworks.opendatasoft.com/pages/glossary/ We are reviewing the terms and conditions under which we share underground cables. Please bear with us.
OpenDataSoft datasetcompatibleProject Enable - Projections for Blue Badge Holders and Parking Bays
UpdatedFeb 11, 2022Introduction As part of our Enable project, we estimated the projected number of on-street disabled parking bays and Blue Badge holders in our licence areas by 2030. This data is available at the Lower Layer Super Output Area (LSOA) level. We hope that this data will help local authorities and charge point operators plan for accessible transport provision for customers. This project started in March 2021 and concluded in March 2022. More information on what we're doing for accessible transport can be found at UK Power Networks Accessible transport information hub and project-enable. Please note, the dataset contains estimations and are not true values. Methodological Approach Details on the methodology can be found in the project report - Project Enable. Quality Control Statement Quality Control Measures include: Manual review and correct of data inconsistencies Use of additional verification steps to ensure accuracy in the methodology Assurance Statement The Open Data Team and Innovation Team worked together to ensure data accuracy and consistency. Other Download dataset information: Metadata (JSON) Definitions of key terms related to this dataset can be found in the Open Data Portal Glossary: https://ukpowernetworks.opendatasoft.com/pages/glossary/
OpenDataSoft datasetunsupportedUK Power Networks Secondary Site Transformers
UpdatedNov 27, 2025Introduction List of transformers associated with UK Power Networks' Published Secondary Sites UK Power Networks Secondary Sites — UK Power Networks (opendatasoft.com) This datasets includes the site functional location, the DNO, Oil Natural Air Natural (ONAN) transformer rating and voltage of each secondary transformer. Methodological Approach Data Extraction: This dataset is extracted from Azure Databricks. Combination: Various data columns are joined in Azure Databricks based on the functional location. This includes Grid Reference, connectivity and the number of customers. Administrative Divisions are found using the Geo Point. Processing: There is some data processing, such as conversion of Grid Reference into longitude and latitude. Quality Control Statement The data is provided "as is". Assurance Statement The Open Data team has checked the data against source to ensure data accuracy and consistency. The data domain owners have checked their respective data aspects. Other Download dataset information: Metadata (JSON) Definitions of key terms related to this dataset can be found in the Open Data Portal Glossary: https://ukpowernetworks.opendatasoft.com/pages/glossary/ To view this data please register and login.
OpenDataSoft datasetcompatibleOpen Data Portal Glossary
UpdatedOct 14, 2026Introduction This dataset contains the terms and definitions included on the UKPN Open Data Portal Glossary Page. Methodological Approach This dataset is sourced from UK Power Networks internal business glossary. Quality Control Statement Quality Control Measures include: Manual review and correction of data inconsistencies Use of additional verification steps to ensure accuracy in the methodology Assurance Statement The Open Data Team and Data Governance Team worked together to ensure data accuracy and consistency. Other UKPN Open Data Portal Glossary helps ensure common understanding of terms, used or related to the datasets published on UKPN Open Data Portal. Download dataset information: Metadata (JSON) Definitions of key terms related to this dataset can be found in the Open Data Portal Glossary: https://ukpowernetworks.opendatasoft.com/pages/glossary/
OpenDataSoft datasetunsupportedNet Zero Use Cases
UpdatedJun 25, 2026Introduction Local area energy planning (LAEP) is fundamental in achieving net zero objectives. Following direct engagement with key stakeholders, 30 use cases were identified within a set of defined data themes. This dataset details those use cases and contains links to the data and / or information required which can be found in the Net Zero Use Cases and Data Requirements dataset. Methodological Approach This dataset is manually updated as and when there is an update. Quality Control Statement Quality Control Measures include: Manual review and correct of data inconsistencies Use of additional verification steps to ensure accuracy in the methodology Assurance Statement The Open Data Team and Local Net Zero Team worked together to ensure data accuracy and consistency. Other Download dataset information: Metadata (JSON) Definitions of key terms related to this dataset can be found in the Open Data Portal Glossary: https://ukpowernetworks.opendatasoft.com/pages/glossary/
OpenDataSoft datasetunsupported33kV Circuit Operational Data Monthly
UpdatedOct 22, 2026Introduction UK Power Network maintains the 132kV voltage level network and below. An important part of the distribution network is distributing this electricity across our regions through circuits. Electricity enters our network through Super Grid Transformers at substations shared with National Grid we call Grid Supply Points. It is then sent at across our 132 kV Circuits towards our grid substations and primary substations. From there, electricity is distributed along the 33 kV circuits to bring it closer to the home. These circuits can be viewed on the single line diagrams in our Long-Term Development Statements (LTDS) and the underlying data is then found in the LTDS tables. Care is taken to protect the private affairs of companies connected to the 33 kV network, resulting in the redaction of certain circuits. Where redacted, we provide monthly statistics to continue to add value where possible. Where monthly statistics exist but half-hourly is absent, this data has been redacted. This dataset provides monthly statistics across these named circuits from 2021 through to the previous month across our license areas. The data is aligned with the same naming convention as the LTDS for improved interoperability. To find half-hourly current and power flow for the circuit you are looking for, use the ‘ltds_line_name’ that can be cross referenced in the EPN and SPN 33kV Circuits Half Hourly data. If you want to download all this data, it is perhaps more convenient from our public sharepoint: Sharepoint This dataset is part of a larger endeavour to share more operational data on UK Power Networks assets. Please visit our Network Operational Data Dashboard for more operational datasets. Methodological Approach The dataset is not derived, it is the measurements from our network stored in our historian. The measurement devices are taken from current transformers attached to the cable at the circuit breaker, and power is derived combining this with the data from voltage transformers physically attached to the busbar. The historian stores datasets based on a report-by-exception process, such that a certain deviation from the present value must be reached before logging a point measurement to the historian. We extract the data following a 30-min time weighted averaging method to get half-hourly values. Where there are no measurements logged in the period, the data provided is blank; due to the report-by-exception process, it may be appropriate to forward fill this data for shorter gaps. We developed a data redactions process to protect the privacy or companies according to the Utilities Act 2000 section 105.1.b, which requires UK Power Networks to not disclose information relating to the affairs of a business. For this reason, where the demand of a private customer is derivable from our data and that data is not already public information (e.g., data provided via Elexon on the Balancing Mechanism), we redact the half-hourly time series, and provide only the monthly averages. This redaction process considers the correlation of all the data, of only corresponding periods where the customer is active, the first order difference of all the data, and the first order difference of only corresponding periods where the customer is active. Should any of these four tests have a high linear correlation, the data is deemed redacted. This process is not simply applied to only the circuit of the customer, but of the surrounding circuits that would also reveal the signal of that customer. The directionality of the data is not consistent within this dataset. Where directionality was ascertainable, we arrange the power data in the direction of the LTDS "from node" to the LTDS "to node". Measurements of current do not indicate directionality and are instead positive regardless of direction. In some circumstances, the polarity can be negative, and depends on the data commissioner's decision on what the operators in the control room might find most helpful in ensuring reliable and secure network operation. Quality Control Statement The data is provided "as is". In the design and delivery process adopted by the DSO, customer feedback and guidance is considered at each phase of the project. One of the earliest steers was that raw data was preferable. This means that we do not perform prior quality control screening to our raw network data. The result of this decision is that network rearrangements and other periods of non-intact running of the network are present throughout the dataset, which has the potential to misconstrue the true utilisation of the network, which is determined regulatorily by considering only by in-tact running arrangements. Therefore, taking the maximum or minimum of these measurements are not a reliable method of correctly ascertaining the true utilisation. This does have the intended added benefit of giving a realistic view of how the network was operated. The critical feedback was that our customers have a desire to understand what would have been the impact to them under real operational conditions. As such, this dataset offers unique insight into that. Assurance Statement Creating this dataset involved a lot of human data imputation. At UK Power Networks, we have differing software to run the network operationally (ADMS) and to plan and study the network (PowerFactory). The measurement devices are intended to primarily inform the network operators of the real time condition of the network, and importantly, the network drawings visible in the LTDS are a planning approach, which differs to the operational. To compile this dataset, we made the union between the two modes of operating manually. A team of data scientists, data engineers, and power system engineers manually identified the LTDS circuit from the single line diagram, identified the line name from LTDS Table 2a/b, then identified the same circuit in ADMS to identify the measurement data tags. This was then manually inputted to a spreadsheet. Any influential customers to that circuit were noted using ADMS and the single line diagrams. From there, a python code is used to perform the triage and compilation of the datasets. There is potential for human error during the manual data processing. These issues can include missing circuits, incorrectly labelled circuits, incorrectly identified measurement data tags, incorrectly interpreted directionality. Whilst care has been taken to minimise the risk of these issues, they may persist in the provided dataset. Any uncertain behaviour observed by using this data should be reported to allow us to correct as fast as possible. Additional Information Definitions of key terms related to this dataset can be found in the Open Data Portal Glossary. Download dataset information:Metadata (JSON) We would be grateful if you find this dataset useful to submit a “reuse” case study to tell us what you did and how you used it. This enables us to drive our direction and gain better understanding for how we improve our data offering in the future. Click here for more information: Open Data Portal Reuses — UK Power Networks To view this data please register and login.
OpenDataSoft datasetcompatibleLong Term Development Statement (LTDS) Table 5 Generation
UpdatedJun 29, 2026Introduction The Long Term Development Statements (LTDS) report on a 0-5 year period, describing a forecast of load on the network and envisioned network developments. The LTDS is published at the end of May and November each year. Long Term Development Statement Table 5 shows the capacity of existing distributed generation connected at each Primary substation. It also includes a snapshot of accepted connections at the time. Published 29th May 2026. More information and full reports are available from the landing page below: Long Term Development Statement Landing Page Methodological Approach Site Functional Locations (FLOCs) are used to associate the Substation to Key characteristics of active Grid and Primary sites — UK Power Networks ID field added to identify row number for reference purposes Quality Control Statement Quality Control Measures include: Verification steps to match features only with confirmed functional locations. Manual review and correction of data inconsistencies. Use of additional verification steps to ensure accuracy in the methodology. Assurance Statement The Open Data Team and Network Insights Team worked together to ensure data accuracy and consistency. Other Download dataset information: Metadata (JSON) Definitions of key terms related to this dataset can be found in the Open Data Portal Glossary: Open Data Portal Glossary To view this data please register and login.
OpenDataSoft datasetunsupportedUK Power Networks Grid Substation Distribution Areas
UpdatedMar 31, 2025Introduction This dataset is a geospatial view of the areas fed by grid substations. The aim is to create an indicative map showing the extent to which individual grid substations feed areas based on MPAN data. Methodology Data Extraction and Cleaning: MPAN data is queried from SQL Server and saved as a CSV. Invalid values and incorrectly formatted postcodes are removed using a Test Filter in FME. Data Filtering and Assignment: MPAN data is categorized into EPN, LPN, and SPN based on the first two digits. Postcodes are assigned a Primary based on the highest number of MPANs fed from different Primary Sites. Polygon Creation and Cleaning: Primary Feed Polygons are created and cleaned to remove holes and inclusions. Donut Polygons (holes) are identified, assigned to the nearest Primary, and merged. Grid Supply Point Integration: Primaries are merged into larger polygons based on Grid Site relationships. ny Primaries not fed from a Grid Site are marked as NULL and labeled. Functional Location Codes (FLOC) Matching: FLOC codes are extracted and matched to Primaries, Grid Sites and Grid Supply Points. Confirmed FLOCs are used to ensure accuracy, with any unmatched sites reviewed by the Open Data Team. Quality Control Statement Quality Control Measures include: Verification steps to match features only with confirmed functional locations. Manual review and correct of data inconsistencies Use of additional verification steps to ensure accuracy in the methodology Regular updates and reviews documented in the version history Assurance Statement The Open Data Team and Network Data Team worked with the Geospatial Data Engineering Team to ensure data accuracy and consistency. Other Download dataset information: Metadata (JSON) Definitions of key terms related to this dataset can be found in the Open Data Portal Glossary: https://ukpowernetworks.opendatasoft.com/pages/glossary/ To view this data please register and login.
OpenDataSoft datasetcompatibleHigh Voltage Flexibility Zones by Tender Round
UpdatedJul 9, 2026Introduction This dataset provides a geospatial view of High Voltage (HV) Flexibility Zones where long-term flexibility services have been tendered for by UK Power Networks. The dataset presents HV Flexibility Zones by tender round, showing whether UK Power Networks was procuring flexibility to manage constraints in a zone relating to high demand (e.g. reduced consumption or increased generation at times of peak demand) or excess generation (e.g. increased consumption or reduced generation at times of excess renewable generation). It is intended to help flexibility service providers understand where long-term HV flexibility requirements have been located over time. For information on the historic delivery of flexibility services, please refer to the Flexibility Dispatches dataset Methodological Approach Each HV Flexibility Zone is shown as a geographic area representing the location of a network constraint. Zones are linked to a specific tender round and indicate whether flexibility was sought for Demand or Generation constraints. These requirements reflect the requirements at the time the flexibility tender was run and may not represent current network needs. As part of the flexibility procurement process, individual meter points (MPANs) are checked to confirm final eligibility. This dataset provides an indicative view of where flexibility has been required by UK Power Networks in the past and does not confirm eligibility to participate in future tenders. Quality Control Statement The dataset is subject to a series of quality control checks prior to publication. These include: Verification of Flexibility Zone boundaries and spatial accuracy; Checks that Flexibility Zone names align with those used in other datasets on the Open Data Portal; and Consistency with zone naming used on Localflex and within competition data files published on the Tender Hub Assurance Statement The High Voltage Flexibility Zones by Tender Round spatial map is reviewed prior to publication by a member of the Flexibility Markets team. Other Download dataset information: Metadata (JSON) Definitions of key terms related to this dataset can be found in the Open Data Portal Glossary: Open Data Portal Glossary To view this data please register and login.
OpenDataSoft datasetcompatibleLong Term Development Statement (LTDS) Table 8 >95% Fault Data
UpdatedJun 29, 2026Introduction The Long Term Development Statements (LTDS) report on a 0-5 year period, describing a forecast of load on the network and envisioned network developments. The LTDS is published at the end of May and November each year. Long Term Development Statement Table 8 indicates any Fault Level restrictions or mitigations in place at our Grid and Primary substations. Published 29th May 2026. More information and full reports are available from the landing page below: Long Term Development Statement Landing Page Methodological Approach Site Functional Locations (FLOCs) are used to associate the Substation to Key characteristics of active Grid and Primary sites — UK Power Networks ID field added to identify row number for reference purposes Quality Control Statement Quality Control Measures include: Verification steps to match features only with confirmed functional locations. Manual review and correction of data inconsistencies. Use of additional verification steps to ensure accuracy in the methodology. Assurance Statement The Open Data Team and Network Insights Team worked together to ensure data accuracy and consistency. Other Download dataset information: Metadata (JSON) Definitions of key terms related to this dataset can be found in the Open Data Portal Glossary: https://ukpowernetworks.opendatasoft.com/pages/glossary/ To view this data please register and login.
OpenDataSoft datasetunsupportedUK Power Networks Secondary Site Utilisation
UpdatedNov 27, 2025Introduction This dataset shows the utilisation band of our secondary sites across our three networks, over 1 April 2024 to 31 March 2025. This dataset is a redacted version of an annual regulatory submission to Ofgem. The data consists of a single utilisation value over a year for each of UK Power Networks secondary substation. This dataset is redacted in that any secondary sites with five or less customers will not be included to protect privacy. This dataset is a mixture of actual utilisation data and analytics based on transformer profile. The utilisation bands do not indicate contractually committed capacity e.g. capacity on our network may be unused now but expected to be used by a connection in a future year, recent acceptances which will be covered in next year's data. If you notice any errors, please let us know by feedbacking against the record in the table tab. Methodological Approach UK Power Networks worked with other DNOs and the Energy Networks Association (ENA), to agree a methodology to calculating transformer utilisation. It considered the following: Transformer rating; Current peak loading; Year demand growth; Year ahead peak demand; and Utilisation calculation. Quality Control Statement This dataset is provided "as is". Assurance Statement The Open Data Team and DSO Network Strategy Team worked to ensure data accuracy and consistency. Other Download dataset information: Metadata (JSON) Definitions of key terms related to this dataset can be found in the Open Data Portal Glossary: https://ukpowernetworks.opendatasoft.com/pages/glossary/ To view this data please register and login.
OpenDataSoft datasetunsupportedLong Term Development Statement (LTDS) Table 6 New Connection Interest
UpdatedSep 21, 2026Introduction The Long Term Development Statements (LTDS) report on a 0-5 year period, describing a forecast of load on the network and envisioned network developments. The LTDS is published at the end of May and November each year. Long Term Development Statement Table 6 indicates the level of new connections interest at each Primary substation. Published 29th May 2026. More information and full reports are available from the landing page below: Long Term Development Statement Landing Page Methodological Approach Site Functional Locations (FLOCs) are used to associate the Site to Key characteristics of active Grid and Primary sites — UK Power Networks ID field added to identify row number for reference purposes Quality Control Statement Quality Control Measures include: Verification steps to match features only with confirmed functional locations. Manual review and correction of data inconsistencies Use of additional verification steps to ensure accuracy in the methodology Assurance Statement The Open Data Team and Network Insights Team worked together to ensure data accuracy and consistency. Other Download dataset information: Metadata (JSON) Definitions of key terms related to this dataset can be found in the Open Data Portal Glossary: Open Data Portal Glossary To view this data please register and login.
OpenDataSoft datasetunsupportedSensitivity Factors (Import)
UpdatedNov 5, 2024Introduction This dataset provides Sensitivity Factors (SFs) for UK Power Networks' three licence areas. SFs represent the marginal impact of a power injection at a node on the network to branches (lines or transformers) elsewhere. They provide a simplified, linearised way of modelling the marginal impact of a MW generated in one part of the network on key constraints and are therefore widely used to model distributed energy resources (DERs) on the network. This analysis can be critical to developers assessing new projects. This dataset is calculated under an Import scenario of maximum demand and minimum generation. Please see the SFs (Export) dataset for sensitivity factors conducted under maximum generation, minimum demand conditions. Methodology: SFs are calculated in PowerFactory based on an AC load flow. When calculating SFs for lines/cables/circuits, SFs are calculated between the node, which is where the import/export of power will take place, and the branch, which is where the change in power will be felt. For example, 1 MW injected at the node would have 0.8 MW decrease at the branch if the SF between the node and branch is -0.8. For transformers, we model between the HV node and the LV node. The SF values given are a fraction, dP/dP, that is, the increase or decrease in MW flow along the branch, resulting from a 1 MW active power injection at the node. The SFs are calculated under static network conditions and in intact running arrangements. They are a useful approximation of network suitable for modelling purposes, but do not reflect the real-time variability resulting from changing running arrangements and network loading. SFs are calculated on a per-Grid Supply Point basis: SFs are not provided between nodes and branches in different Grid Supply Points. Interoperability: This dataset is interoperable with our Long Term Development Statement (LTDS) publications. Nodes can be matched with LV or HV node names in Tables 2a and 2b, while branches can be linked with the lines reported in Table 1 and transformers in Tables 2a and 2b. Using these datasets, users can retrieve asset ratings to assist curtailment studies. Quality Control Statement This dataset is subjected to algorithmic tests to ensure the data is clean. In addition, interoperability tests ensure that the dataset can be linked with tables from the Long Term Development Statement, also available on the Open Data Portal. Assurance Statement Sensitivity Factors are produced by UK Power Networks engineers, based on up-to-date PowerFactory models. The data is also reviewed by DSO data scientists before publication on the Open Data Portal. Download dataset information: Metadata (JSON) Definitions of key terms related to this dataset can be found in the Open Data Portal Glossary: https://ukpowernetworks.opendatasoft.com/pages/glossary/ To view this data please register and login.
OpenDataSoft datasetcompatibleUK Power Networks Visual Amenity Projects
UpdatedNov 18, 2026Introduction List of UK Power Network's Visual Amenity Projects where overhead power lines have been removed from National Landscapes and National Parks, restoring the British countryside to its beautiful best. Click here to view geographically and find out more about our Projects. Methodological Approach The Property and Consents team provided this dataset from their source. Quality Control Statement This dataset is provided "as is". Assurance Statement The Open Data Team and Property and Consents Team worked together to ensure data accuracy and consistency. Other Download dataset information: Metadata (JSON) Definitions of key terms related to this dataset can be found in the Open Data Portal Glossary: https://ukpowernetworks.opendatasoft.com/pages/glossary/
OpenDataSoft datasetunsupportedFlexibility Tender Data by Postcode
UpdatedJul 22, 2026Introduction This dataset provides information on where UK Power Networks requires flexibility services. The dataset provides a mapping of postcodes to Flexibility Zones – for all existing and historic day-ahead and long-term flexibility requirements. This enables potential flexibility service providers to quickly understand their eligibility for revenue from flexibility, without sharing any sensitive personal or commercial information. This dataset provides an approximation of eligibility for our flexibility tenders. Please note that even if your asset is within a postcode listed in this dataset, as part of the flexibility procurement process we will need to validate that the individual meter point (MPAN) is electrically connected to the Flexibility Zone. Methodological Approach Postcodes are listed against a Flexibility Zone where at least one meter point within that postcode is electrically connected to the constrained network asset. For large Flexibility Zones, which cover multiple postcodes, this will be a very good indication of eligibility for flexibility services. For smaller Flexibility Zones, particularly those at Low Voltage, a significant proportion of properties within a listed postcode may ultimately not be eligible. As part of our flexibility procurement process, we will check the individual meter point (MPAN) to confirm its final eligibility. This dataset offers an approximation of eligibility, without requiring any sharing of household or business level data. Quality Control Statement Dispatches are passed through a quality control algorithm to flag anomalies and erroneous data. Quality control checks include: Checking the formatting of postcodes; Checking the number of postcodes mapped to each Flexibility Zone; and Checking that Flexibility Zone names align with those in other datasets on the Open Data Portal and on UK Power Networks’ chosen flexibility market platform: www.localflex.co.uk Assurance Statement The Flex Zone to Postcode mapping is reviewed before publication by a member of Flexibility Markets team. Other Download dataset information: Metadata (JSON) Definitions of key terms related to this dataset can be found in the Open Data Portal Glossary: https://ukpowernetworks.opendatasoft.com/pages/glossary/ To view this data please register and login.
OpenDataSoft datasetunsupportedGrid Transformer Power Flow Historic Monthly
UpdatedOct 17, 2026Introduction UK Power Network maintains the 132kV voltage level network and below. An important part of the distribution network is the stepping down of voltage as it is moved towards the household; this is achieved using transformers. Transformers have a maximum rating for the utilisation of these assets based upon protection, overcurrent, switch gear, etc. This dataset contains the Grid Substation Transformers, also known as Bulk Supply Points, that typically step-down voltage from 132kV to 33kV (occasionally down to 66 or more rarely 20-25). These transformers can be viewed on the single line diagrams in our Long-Term Development Statements (LTDS) and the underlying data is then found in the LTDS tables. Care is taken to protect the private affairs of companies connected to the 33kV network, resulting in the redaction of certain transformers. Where redacted, we provide monthly statistics to continue to add value where possible. Where monthly statistics exist but half-hourly is absent, this data has been redacted. This dataset provides monthly statistics data across these named transformers from 2023 through to the previous month across our licence areas. The data are aligned with the same naming convention as the LTDS for improved interoperability. To find half-hourly current and power flow data for a transformer, use the ‘tx_id’ that can be cross referenced in the Grid Transformers Half Hourly Dataset. If you want to download all this data, it is perhaps more convenient from our public sharepoint: Open Data Portal Library - Grid Transformers - All Documents (sharepoint.com) This dataset is part of a larger endeavour to share more operational data on UK Power Networks assets. Please visit our Network Operational Data Dashboard for more operational datasets. Methodological Approach The dataset is not derived, it is the measurements from our network stored in our historian. The measurement devices are taken from current transformers attached to the cable at the circuit breaker, and power is derived combining this with the data from voltage transformers physically attached to the busbar. The historian stores datasets based on a report-by-exception process, such that a certain deviation from the present value must be reached before logging a point measurement to the historian. We extract the data following a 30-min time weighted averaging method to get half-hourly values. Where there are no measurements logged in the period, the data provided is blank; due to the report-by-exception process, it may be appropriate to forward fill this data for shorter gaps. We developed a data redactions process to protect the privacy or companies according to the Utilities Act 2000 section 105.1.b, which requires UK Power Networks to not disclose information relating to the affairs of a business. For this reason, where the demand of a private customer is derivable from our data and that data is not already public information (e.g., data provided via Elexon on the Balancing Mechanism), we redact the half-hourly time series, and provide only the monthly averages. This redaction process considers the correlation of all the data, of only corresponding periods where the customer is active, the first order difference of all the data, and the first order difference of only corresponding periods where the customer is active. Should any of these four tests have a high linear correlation, the data is deemed redacted. This process is not simply applied to only the circuit of the customer, but of the surrounding circuits that would also reveal the signal of that customer. The directionality of the data is not consistent within this dataset. Where directionality was ascertainable, we arrange the power data in the direction of the LTDS "from node" to the LTDS "to node". Measurements of current do not indicate directionality and are instead positive regardless of direction. In some circumstances, the polarity can be negative, and depends on the data commissioner's decision on what the operators in the control room might find most helpful in ensuring reliable and secure network operation. Quality Control Statement The data is provided "as is". In the design and delivery process adopted by the DSO, customer feedback and guidance is considered at each phase of the project. One of the earliest steers was that raw data was preferable. This means that we do not perform prior quality control screening to our raw network data. The result of this decision is that network rearrangements and other periods of non-intact running of the network are present throughout the dataset, which has the potential to misconstrue the true utilisation of the network, which is determined regulatorily by considering only by in-tact running arrangements. Therefore, taking the maximum or minimum of these transformers are not a reliable method of correctly ascertaining the true utilisation. This does have the intended added benefit of giving a realistic view of how the network was operated. The critical feedback was that our customers have a desire to understand what would have been the impact to them under real operational conditions. As such, this dataset offers unique insight into that. Assurance Statement Creating this dataset involved a lot of human data imputation. At UK Power Networks, we have differing software to run the network operationally (ADMS) and to plan and study the network (PowerFactory). The measurement devices are intended to primarily inform the network operators of the real time condition of the network, and importantly, the network drawings visible in the LTDS are a planning approach, which differs to the operational. To compile this dataset, we made the union between the two modes of operating manually. A team of data scientists, data engineers, and power system engineers manually identified the LTDS transformer from the single line diagram, identified the line name from LTDS Table 2a/b, then identified the same transformer in ADMS to identify the measurement data tags. This was then manually inputted to a spreadsheet. Any influential customers to that circuit were noted using ADMS and the single line diagrams. From there, a python code is used to perform the triage and compilation of the datasets. There is potential for human error during the manual data processing. These issues can include missing transformers, incorrectly labelled transformers, incorrectly identified measurement data tags, incorrectly interpreted directionality. Whilst care has been taken to minimise the risk of these issues, they may persist in the provided dataset. Any uncertain behaviour observed by using this data should be reported to allow us to correct as fast as possible. Additional information Definitions of key terms related to this dataset can be found in the Open Data Portal Glossary. Download dataset information: Metadata (JSON) We would be grateful if you find this dataset useful to submit a “reuse” case study to tell us what you did and how you used it. This enables us to drive our direction and gain better understanding for how we improve our data offering in the future. Click here for more information: Open Data Portal Reuses — UK Power Networks To view this data please register and login.
OpenDataSoft datasetcompatibleSmart Meter Installation Volumes by LSOA
UpdatedOct 19, 2026Introduction A monthly updated snapshot of the number of meters connected by local authority district and Lower Layer Super Output Area (LSOA) and by meter category: smart (smart and advanced); and not smart (analogue). Specifically, our smart meter definition is: Profile Class 0-4 meters only; and Meters in Measurement Class A,F and G only. Note 1: where UK Power Networks borders NGED and SSEN, and share coverage of common local authorities, only UK Power Networks customers connected to the UK Power Networks are shown. Note 2: the smart meters are mapped to LSOA using Office for National Statistics datasets which are updated annually. However, UK Power Networks smart meter installation counts are updated monthly so there is a natural but negligible discrepancy. Contains Local Authority district code and name and LSOA (lower layer super output area) code and name sourced from the Office for National Statistics (ONS) licensed under the Open Government Licence v.3.0 Methodological Approach Data Extraction and Cleaning: Smart Meter installation data is extracted by postcode, such that each post code has a count for smart meters; analogue; and advanced. Aggregation: Each post code is assigned to an LSOA and local authority using ONS data. Polygon Creation: Each LSOA is then assigned to a polygon. Quality Control Statement Quality Control Measures include: Data only shown with confirmed postcode to LSOA mapping Manual review and correction of data inconsistencies Assurance Statement The Open Data Team and Income Management Team worked together to ensure data accuracy and consistency. Other Download dataset information: Metadata (JSON) Definitions of key terms related to this dataset can be found in the Open Data Portal Glossary: https://ukpowernetworks.opendatasoft.com/pages/glossary/
OpenDataSoft datasetcompatibleGrid Site Transformers
UpdatedJun 3, 2026Introduction Active transformer characteristics from our Grid Sites. Methodological Approach Data stems from our data warehouse; and Site Functional Location (FLOC) is used to capture spatial coordinates from Key characteristics of active Grid and Primary sites — UK Power Networks. Quality Control Statement Quality Control Measures include: Verification steps to match features only with confirmed functional locations. Manual review and correction of data inconsistencies Use of additional verification steps to ensure accuracy in the methodology Assurance Statement The Open Data Team has checked to ensure data accuracy and consistency. Other Download dataset information: Metadata (JSON) Definitions of key terms related to this dataset can be found in the Open Data Portal Glossary: Open Data Portal Glossary To view this data please register and login.
OpenDataSoft datasetcompatibleNational Parks
UpdatedApr 16, 2024National Parks are run by National Park Authorities for the purpose of conserving and enhancing the natural beauty, wildlife and cultural heritage and to provide opportunities for the understanding and enjoyment of the Park by the public. This dataset is restricted to the UK Power Networks' three licence areas. Methodological approach Download and ingestions: That dataset was downloaded from the Department for Environment Food and Rural Affairs data portal, and ingested into this data portal. Quality Control Statement This dataset is provided "as is". Assurance Statement The Open Data Team has reviewed the dataset to ensure it is true to source. Other Download dataset information: Metadata (JSON) Definitions of key terms related to this dataset can be found in the Open Data Portal Glossary: https://ukpowernetworks.opendatasoft.com/pages/glossary/
OpenDataSoft datasetunsupportedUK Power Networks' Pipeline Allocation
UpdatedAug 18, 2026Introduction The data shown above constitutes UK Power Networks’ provisional view against the Clean Power 2030 technology breakdowns applicable to UK Power Networks – the information will continue to be updated as we confirm the evidence from our customers. This is for indicative purposes only. Here is a breakdown of the different categories: Connected: Connected capacity. Potentially Protected Schemes by 2030: Projects meeting any of the protections criteria against Strategic Alignment. In line with the Connections Network Design Methodology (CNDM) from NESO, if the 2030 permitted capacity is reached at this stage, all remaining potentially protected projects will be allocated to Phase 2 (2035 allocation), even if this results in 2035 permitted capacity being exceeded. Potentially Protected Schemes by 2035: Remaining projects meeting any of the protections criteria against Strategic Alignment, and which exceeded the 2030 permitted capacity. Projects with readiness connecting by 2030: Projects with land rights (and either application submitted, under appeal or only land), connecting by 2030 as per their contracted connection date. Projects with readiness connecting by 2035: Projects with land rights (and either application submitted, under appeal or only land), connecting by 2035 as per their contracted connection date. No readiness or progress recorded: Projects without land rights (despite having consents approved or application submitted), or no progress recorded at all. Outside of scope for Gate 2 to Whole Queue: Projects which fall outside of the upcoming Gate 2 application window (Gate 2 to Whole Queue) due to not being part of an application to NESO before “The Pause” . Clean Power Action Plan - 2030: Regional capacity breakdown per technologies for UK Power Networks’ distribution network region for 2030, as provided by the Clean Power 2030 Action Plan (Clean Power 2030 Action Plan: A new era of clean electricity: Connections reform annex) Clean Power Action Plan - 2035: Regional capacity breakdown per technologies for UK Power Networks’ distribution network region for 2035, as provided by the Clean Power 2030 Action Plan (Clean Power 2030 Action Plan: A new era of clean electricity: Connections reform annex) Methodological Approach The breakdown has been generated based on the progress status which aligns with NESO’s Gate 2 Readiness Criteria, compared against DESNZ allocation for UK Power Networks. This continues to be updated as more information is provided and validated. Quality Control Statement This dataset has been peer reviewed and is the outcome of an iterative process as the queue formation process has become clearer over the last months (and is still subject to change following Ofgem’s decision). Assurance Statement The Open Data Team and DSO Regional Development Team worked together ensure data accuracy and consistency. Other Download dataset information: Metadata (JSON) Definitions of key terms related to this dataset can be found in the Open Data Portal Glossary: https://ukpowernetworks.opendatasoft.com/pages/glossary/
OpenDataSoft datasetunsupportedSolar Power Land Suitability (IRENES)
UpdatedJun 26, 2024Introduction This dataset provides the locations of areas that restrict the suitability of land for solar PV developments; such as roads, residential areas, world heritage sites, agricultural land, and flood zones. In addition, it calculates the potential energy density of over 3.5 million individual areas for both solar and wind installations using windspeed and solar irradiance data. This results in an overall assessment of the suitability of a specific area for installing solar and wind generation. The assessment grades land as either YES – suitable, No – not suitable, or MAYBE – could be suitable. This dataset was developed for UK Power Networks licence area by UEA Consulting Limited. It is based on public domain sources and previous analysis that was carried out as part of the IRENES EU Interreg project which examined renewable energy sources in eastern England. Methodological Approach To view the methodology behind this data please click here. This dataset displays the solar PV data, click here for the wind data. Quality Control Statement This dataset is provided "as is". Assurance Statement The Open Data Team and Local Net Zero Team worked together to ensure data accuracy and consistency. Other Download dataset information: Metadata (JSON) Definitions of key terms related to this dataset can be found in the Open Data Portal Glossary: https://ukpowernetworks.opendatasoft.com/pages/glossary/ To view this data please register and login.
OpenDataSoft datasetunsupportedLondon Power Networks (LPN) Vectorisation Delivery Plan
UpdatedNov 26, 2026Introduction The GIS (Geographic Information System) vectorisation project will deliver the incremental digital conversion of our legacy geospatial network records. This dataset defines the sub-areas which will be incrementally delivered, detailing corresponding current status and planned completion dates. This allows users to understand the current and future coverage of digital geospatial network records as the project progresses. Methodological Approach Progress against a defined project plan is captured and updated throughout the day. A script is run to convert into a shapefile. This shapefile is then uploaded onto the Open Data Portal. Quality Control Statement This dataset is provided "as is". Assurance Statement The Open Data Team has checked outputs to validate. Other Download dataset information: Metadata (JSON) Definitions of key terms related to this dataset can be found in the Open Data Portal Glossary: https://ukpowernetworks.opendatasoft.com/pages/glossary/
OpenDataSoft datasetcompatibleData Centre Demand Profiles
UpdatedNov 1, 2026Introduction This dataset shows the half-hourly load profiles of identified data centres within UK Power Networks' licence areas. The loads have been determined using actual demand data from connected sites within UK Power Networks' licence areas, from 1 January 2023 onwards. Loads are expressed proportionally, by comparing the half-hourly observed import power seen across the site's meter point(s), against the meter's maximum import capacity. Units for both measures are apparent power, in kilovolt amperes (kVA). To protect the identity of the sites, data points have been anonymised and only the site's voltage level information - and our estimation of the data centre type - has been provided. Methodological Approach Nearly 100 operational data centre sites (and at least 10 per voltage level) were identified through internal desktop exercises and corroboration with external sources. After identifying these sites, their addresses, connection point, and MPAN(s) (Meter Point Administration Number(s)) were identified using internal systems. Half-hourly smart meter import data were retrieved using internal systems. This included both half-hourly meter data, and static data (such as the MPAN's maximum import capacity and voltage group, the latter through the MPAN's Line Loss Factor Class Description). Half-hourly meter import data came in the form of active and reactive power, and the apparent power was calculated using the power triangle. In cases where there are numerous meter points for a given data centre site, the observed import powers across all relevant meter points were summed, and compared against the sum total of maximum import capacity for the meters. The percentage utilisation for each half-hour for each data centre was determined via the following equation: % Utilisation_data centre site = SUM( S_MPAN half-hourly observed import) SUM( S_MPAN Maximum Import Capacity) Where S = Apparent Power in kilovolt amperes (kVA) To ensure the dataset includes only operational data centres, the dataset was then cleansed to exclude sites where utilisation was consistently at 0% across the year. Based on the MPAN's address and corroboration with other open data sources, a data centre type was derived: either enterprise (i.e. company-owned and operated), or co-located (i.e. one company owns the data centre, but other customers operate IT load in the premises as tenants). Each data centre site was then anonymised by removing any identifiers other than voltage level and UK Power Networks' view of the data centre type. Quality Control Statement The dataset is primarily built upon customer smart meter data for connected customer sites within the UK Power Networks' licence areas. The smart meter data that is used is sourced from external providers. While UK Power Networks does not control the quality of this data directly, these data have been incorporated into our models with careful validation and alignment. Any missing or bad data has been addressed though robust data cleaning methods, such as omission. Assurance Statement The dataset is generated through a manual process, conducted by the Distribution System Operator's Regional Development Team. The dataset will be reviewed quarterly - both in terms of the operational data centre sites identified, their maximum observed demands and their maximum import capacities - to assess any changes and determine if updates of demand specific profiles are necessary. Deriving the data centre type is a desktop-based process based on the MPAN's address and through corroboration with external, online sources. This process ensures that the dataset remains relevant and reflective of real-world data centre usage over time. There are sufficient data centre sites per voltage level to assure anonymity of data centre sites. Other Definitions of key terms related to this dataset can be found in the Open Data Portal Glossary: https://ukpowernetworks.opendatasoft.com/pages/glossary/ Download dataset information: Metadata (JSON) To view this data please register and login.
OpenDataSoft datasetcompatibleSmart Meter Consumption - Substation
UpdatedNov 9, 2026Introduction This dataset presents a sample of import aggregated consumption data from Smart Meter customers at the secondary substation level, along with the count of smart meters contributing to the aggregated half-hourly values. It includes both Active Energy Import and Reactive Energy Import readings. The sample comprises 10,000 records drawn from aggregated smart meter data across our three operational regions: Eastern Power Networks (EPN), London Power Networks (LPN), and South Eastern Power Networks (SPN). To access the historical data covering all sites, where there are more than 5 connected smart meters, please see the attached instructions or click here. Methodological Approach Primary consumption data for Active Energy Import is aggregated based on the number of active devices reporting during each half-hour period. If a device is unreachable during a given interval, its data is excluded from the aggregation to maintain accuracy. Quality Control Statement We are conducting monthly validation checks to enhance data quality prior to releasing the full dataset. Users are advised to exercise caution when interpreting or utilising this preliminary data. Please note that smart meter readings rely on accurate hardware installed by energy suppliers. Some devices have known issues with the accuracy of measurements which may impact the aggregate numbers provided. We do conduct sense checks on an invalid readings and may exclude impossible values. Assurance Statement The Smart Metering Team has reviewed the dataset to ensure consistency and accuracy in the presented data. Other Definitions of key terms related to this dataset can be found in the Open Data Portal Glossary: Open Data Portal Glossary Download dataset information: Metadata (JSON) To view this data please register and login.
OpenDataSoft datasetunsupportedNewsFeed
UpdatedNov 20, 2026Introduction Newsfeed Dataset lists the news items shown the landing page preview window. Other Download dataset information: Metadata (JSON) Definitions of key terms related to this dataset can be found in the Open Data Portal Glossary: https://ukpowernetworks.opendatasoft.com/pages/glossary/
OpenDataSoft datasetunsupportedUK Power Networks Secondary Sites
UpdatedJun 15, 2026Introduction This dataset shows our secondary sites and a number of attributes including oil natural air natural (ONAN) ratings, spatial coordinates, customer counts, whether a site is indoor/outdoor, the address, substation name, alias and its primary feeder. Note: as of 18 April 2024, we have included an additional column showing the utilisation band of the site. The utilisation bands do not indicate contractually committed capacity e.g. capacity on our network may be unused now but expected to be used by a connection in a future year, recent acceptances which will be covered in next year's data. There is a site classification as follows: GMT: Ground Mounted Transformer; and PMT: Pole Mounted Transformer. As per the attached triage document, we have redacted sites from this dataset where a transformer serves five or less customers, as well as Independent Distribution Network Operator (IDNO) sites. This is in the interest of protecting customer privacy. Further, we are aware that for a small number of records there are null values, this is primarily for the rare cases where sites have more than one transformer. There is an ongoing review into how this is recorded, which will be reflected in the data once resolved. If you notice any errors, please let us know by feedbacking against the record in the table tab. Methodological Approach Data Extraction: This dataset is extracted from Azure Databricks; Combination: Various data columns are joined in Azure Databricks based on the FLOC. This includes Grid Reference, connectivity and the number of customers; and Processing: There are some processing, such as conversion of Grid Reference into longitude and latitude. Quality Control Statement Quality Control Measures include: Verification steps to match features only with confirmed functional locations; Manual review and correct of data inconsistencies; and Use of additional verification steps to ensure accuracy in the methodology. Assurance Statement The Open Data Team checked to ensure data accuracy and consistency. Other Download dataset information: Metadata (JSON) Definitions of key terms related to this dataset can be found in the Open Data Portal Glossary:https://ukpowernetworks.opendatasoft.com/pages/glossary/ To view this data please register and login.
OpenDataSoft datasetcompatiblePrimary Transformer Power Flow Historic Half Hourly - Eastern Power Networks
UpdatedNov 12, 2026Introduction UK Power Network maintains the 132kV voltage level network and below. An important part of the distribution network is the stepping down of voltage as it is moved towards the household; this is achieved using transformers. Transformers have a maximum rating for the utilisation of these assets based upon protection, overcurrent, switch gear, etc. This dataset contains the Primary Substation Transformers, that typically step-down voltage from 33kVto 11kV (occasionally from 132kV to 11kV). These transformers can be viewed on the single line diagrams in our Long-Term Development Statements (LTDS) and the underlying data is then found in the LTDS tables. This dataset provides half-hourly current and power flow data across these named transformers, in our Eastern Power Networks region, from 2023 through to the previous month across our licence areas. The data are aligned with the same naming convention as the LTDS for improved interoperability. Care is taken to protect the private affairs of companies connected to the 11kV network, resulting in the redaction of certain transformers. Where redacted, we provide monthly statistics to continue to add value where possible. Where monthly statistics exist but half-hourly is absent, this data has been redacted. To find which transformer you are looking for, use the ‘tx_id’ that can be cross referenced in the Primary Transformers Monthly Dataset, which describes by month what transformers were triaged, if they could be made public, and what the monthly statistics are of that site. If you want to download all this data, it is perhaps more convenient from our public sharepoint: Sharepoint This dataset is part of a larger endeavour to share more operational data on UK Power Networks assets. Please visit our Network Operational Data Dashboard for more operational datasets. Methodological Approach The dataset is not derived, it is the measurements from our network stored in our historian. The measurement devices are taken from current transformers attached to the cable at the circuit breaker, and power is derived combining this with the data from voltage transformers physically attached to the busbar. The historian stores datasets based on a report-by-exception process, such that a certain deviation from the present value must be reached before logging a point measurement to the historian. We extract the data following a 30-min time weighted averaging method to get half-hourly values. Where there are no measurements logged in the period, the data provided is blank; due to the report-by-exception process, it may be appropriate to forward fill this data for shorter gaps. We developed a data redactions process to protect the privacy or companies according to the Utilities Act 2000 section 105.1.b, which requires UK Power Networks to not disclose information relating to the affairs of a business. For this reason, where the demand of a private customer is derivable from our data and that data is not already public information (e.g., data provided via Elexon on the Balancing Mechanism), we redact the half-hourly time series, and provide only the monthly averages. Where the primary transformer has 5 or fewer customers, we redact the dataset. The directionality of the data is not consistent within this dataset. Where directionality was ascertainable, we arrange the power data in the direction of the LTDS "from node" to the LTDS "to node". Measurements of current do not indicate directionality and are instead positive regardless of direction. In some circumstances, the polarity can be negative, and depends on the data commissioner's decision on what the operators in the control room might find most helpful in ensuring reliable and secure network operation. Quality Control Statement The data is provided "as is". In the design and delivery process adopted by the DSO, customer feedback and guidance is considered at each phase of the project. One of the earliest steers was that raw data was preferable. This means that we do not perform prior quality control screening to our raw network data. The result of this decision is that network rearrangements and other periods of non-intact running of the network are present throughout the dataset, which has the potential to misconstrue the true utilisation of the network, which is determined regulatorily by considering only by in-tact running arrangements. Therefore, taking the maximum or minimum of these transformers are not a reliable method of correctly ascertaining the true utilisation. This does have the intended added benefit of giving a realistic view of how the network was operated. The critical feedback was that our customers have a desire to understand what would have been the impact to them under real operational conditions. As such, this dataset offers unique insight into that. Assurance Statement Creating this dataset involved a lot of human data imputation. At UK Power Networks, we have differing software to run the network operationally (ADMS) and to plan and study the network (PowerFactory). The measurement devices are intended to primarily inform the network operators of the real time condition of the network, and importantly, the network drawings visible in the LTDS are a planning approach, which differs to the operational. To compile this dataset, we made the union between the two modes of operating manually. A team of data scientists, data engineers, and power system engineers manually identified the LTDS transformer from the single line diagram, identified the line name from LTDS Table 2a/b, then identified the same transformer in ADMS to identify the measurement data tags. This was then manually inputted to a spreadsheet. Any influential customers to that circuit were noted using ADMS and the single line diagrams. From there, a python code is used to perform the triage and compilation of the datasets. There is potential for human error during the manual data processing. These issues can include missing transformers, incorrectly labelled transformers, incorrectly identified measurement data tags, incorrectly interpreted directionality. Whilst care has been taken to minimise the risk of these issues, they may persist in the provided dataset. Any uncertain behaviour observed by using this data should be reported to allow us to correct as fast as possible. Additional information Definitions of key terms related to this dataset can be found in the Open Data Portal Glossary. Download dataset information: Metadata (JSON) We would be grateful if you find this dataset useful to submit a “reuse” case study to tell us what you did and how you used it. This enables us to drive our direction and gain better understanding for how we improve our data offering in the future. Click here for more information: Open Data Portal Reuses — UK Power Networks To view this data please register and login.
OpenDataSoft datasetcompatibleStandard Profiles UK Power Networks Uses for Electricity Generation
UpdatedDec 3, 2024Introduction The dataset captures yearly generation profiles for different generation technology types, used by UK Power Networks to run export curtailment assessment studies. UK Power Networks has been running curtailment studies since 2014 in the three licence areas and have been using standards technology specific profiles to model the accepted not yet connected generation capacity. Generation specific profile include the following generation types: solar photovoltaic, wind, battery and non-variable generation. The profiles have been developed using actual generation data from connected sites within UK Power Networks licence areas falling into each of the generation categories. The output is a yearly profile with half hourly granularity. The values are expressed as load factors (percentages) i.e., at each half hour the value can range from 0% to 100% of the maximum export capacity. The profiles are revised on a regular basis to ensure that they represent as closely as possible the operational behaviour of unconnected sites. The following change have taken place since UK Power Networks has started issuing curtailment reports: The solar profile was updated in 2019/2020 and capacity factor was increased from 13.2% to 14.2%; The electricity storage profiles were updated in April 2024. new profiles available:“Storage_export_enhanced” and “Storage_import_enhanced”; Gas profiles were updated in September 2024 differentiating between small and large gas generators. Methodological Approach This section outlines the methodology for generating annual half-hourly demand profiles. Connected metered generators falling in each of the categories have been used to create the representative profiles. Historical data from each of these connected generation sites are retrieved from UK Power Networks’ Remote Terminal Unit (RTU) and consist of annual half-hourly meter readings. The profiles are averages of power/capacity at every time period i.e.: Paverage,t = average(P1,tc1 + P2,tc2 + … + Pn,tcn) where t is time, 30 minutes resolution for one year; P is the export in MW from sites 1, 2, ..., n; and c is capacity of site 1, 2, ..., n. If there was bad/missing data then PVSYST and local meteorological data were used. Electricity Storage profiles For export/generation studies, storage is modelled as constantly exporting with a varying profile throughout the day, whereas for demand/import studies, storage is modelled as constantly importing with a varying import profile throughout the day. This represent a conservative view, which is used due to the unpredictable pattern of Electricity Storage sites The solar and storage combined profile is calculated as the maximum of the storage and solar profiles during each 30-minute timestamp. Storage profiles are detailed in our design standard Engineering Design Standard (EDS 08-5010). Storage profiles were updated in April 2024 based following a piece of work delivered by Regen to UK Power Networks on the operational behaviour of battery storage, with the purpose to model reflect battery storage more realistically in curtailment studies . the revised profile are “Storage_export_enhanced” and “Storage_import_enhanced”. Curtailment reports issued prior to 22 April 2024 were produced using the legacy storage profiles (“Storage”). Gas Profiles Gas profiles were updated in September 2024 to provide a more representative view on how gas generator operate and to enable more representative curtailment results. The legacy profile used to model unconnected gas generators until September 2024 was the “non-variable” profiles. From September 2024, unconnected gas generators are modelled using new “Gas_large” and “Gas_small” profile. The two profiles are meant to capture the differences between smaller genset, quickly ramping up from 0 to maximum capacity, and larger gas generators that rather have a more stable behaviour. The profile have been created with the same equation described above, taking a percentile between 95 and 98, rather than the average. Quality Control Statement Quality Control Measures include: Manual review and correct of data inconsistencies Use of additional verification steps to ensure accuracy in the methodology Assurance Statement The Open Data Team and DSO Data Science worked together to ensure data accuracy and consistency. Other Download dataset information: Metadata (JSON) Definitions of key terms related to this dataset can be found in the Open Data Portal Glossary: https://ukpowernetworks.opendatasoft.com/pages/glossary/
OpenDataSoft datasetunsupportedUK Power Networks Licence Area 132kV Poles and Towers
UpdatedSep 22, 2026Introduction A dataset showing the location of UK Power Networks' 132kV towers. Methodological Approach Data Extraction: Shapefiles are extracted from our geospatial mapping system - NetMap. Quality Control Statement The data is provided "as is". Assurance Statement The Open Data Team checked to ensure data accuracy and consistency. Other Download dataset information: Metadata (JSON) Definitions of key terms related to this dataset can be found in the Open Data Portal Glossary: https://ukpowernetworks.opendatasoft.com/pages/glossary/ To view this data please register and login.
OpenDataSoft datasetcompatibleSuper Grid Transformer Power Flow Historic
UpdatedNov 26, 2026Introduction Daily Demand Statistics (Minimum, Average, Maximum) for Grid Supply Point (GSP). It includes aggregated GSP Data for all the monitored GSPs, and it also includes SGT data if we have used those for the creation of aggregated data. Data includes Voltages, Current, Active Power, and Reactive Power, and is populated from 2021 onwards to the current day. This dataset shows data from a sample of GSPs which account for 1/5th of the total GSPs in our area (we will add more sites across the network in the future). This data is refreshed every day at midnight. The data is published as is from the network. Methodological Approach The power flow data is streamed from our PI server into an FTP server before being published on the Open Data Portal. To streamline and enable faster data refresh, we have structured our data into a header file which is light. Quality Control Statement The data is published as is from the network. Assurance Statement The Open Data Team and DSO Data Science Team worked together to ensure data accuracy and consistency. Other Download dataset information: Metadata (JSON) Definitions of key terms related to this dataset can be found in the Open Data Portal Glossary: Open Data Portal Glossary To view this data please register and login.
OpenDataSoft datasetunsupportedProposed Street and Roadworks associated with UK Power Networks' activities
UpdatedNov 26, 2026Introduction To ensure we deliver a safe and reliable electricity supply or to invest in our network, we may need to carry out works on highways and footways. This dataset contains details of our proposed street and roadwork permit applications taking place on the highway within UK Power Networks' footprint. This report is refreshed daily. For further information including contact details, please visit https://www.ukpowernetworks.co.uk/our-company/road-works Methodological Approach Data Extraction: Data is extracted from Street Manager onto a server every two hours. Data Upload: Another script is run every two hours to upload onto an FTP server, before passing onto the Open Data Portal. Quality Control Statement Quality Control Measures include: Manual review and correction of data inconsistencies Use of additional verification steps to ensure accuracy in the methodology Assurance Statement The Open Data Team and Streetworks Team worked together to ensure data accuracy and consistency. Other Definitions of key terms related to this dataset can be found in the Open Data Portal Glossary: Open Data Portal Glossary Download dataset information: Metadata (JSON)
OpenDataSoft datasetunsupportedUK Power Networks Licence Area Statutory Rivers
UpdatedJun 9, 2026Introduction Shapefile showing the rivers within UK Power Networks' three licence areas. Methodological Approach Data Extraction and Cleaning: Data is downloaded from DEFRA data portal. Data Filtering and Assignment: Only rivers within the UK Power Networks service area are included. Quality Control Statement Quality Control Measures include: Manual review and correct of data inconsistencies Use of additional verification steps to ensure accuracy in the methodology Assurance Statement The Open Data Team has checked this to ensure data accuracy and consistency. Other Contains public sector information licensed under the Open Government Licence v3.0. Download dataset information: Metadata (JSON) Definitions of key terms related to this dataset can be found in the Open Data Portal Glossary: https://ukpowernetworks.opendatasoft.com/pages/glossary/
OpenDataSoft datasetconvertibleLong Term Development Statement (LTDS) Table 4b Fault level data - Earth
UpdatedOct 5, 2026Introduction The Long Term Development Statements (LTDS) report on a 0-5 year period, describing a forecast of load on the network and envisioned network developments. The LTDS is published at the end of May and November each year. This is Table 4b from our current LTDS report (published 29th May 2026), showing the earth fault level at each Grid and Primary substation. More information and full reports are available from the landing page below: Long Term Development Statement Landing Page Methodological Approach Site Functional Locations (FLOCs) are used to associate the Substation to Key characteristics of active Grid and Primary sites — UK Power Networks ID field added to identify row number for reference purposes Quality Control Statement Quality Control Measures include: Verification steps to match features only with confirmed functional locations. Manual review and correction of data inconsistencies. Use of additional verification steps to ensure accuracy in the methodology. Assurance Statement The Open Data Team and Network Insights Team together ensure data accuracy and consistency. Other Download dataset information: Metadata (JSON) Definitions of key terms related to this dataset can be found in the Open Data Portal Glossary: https://ukpowernetworks.opendatasoft.com/pages/glossary/ To view this data please register and login.
OpenDataSoft datasetunsupportedUK Power Networks Licence Area 66kV Overhead Lines
UpdatedSep 22, 2026Introduction Shapefile showing UK Power Networks' 66kV overhead lines. Methodological Approach Data Extraction: Shapefiles are extracted from our geospatial mapping system - NetMap. Quality Control Statement The data is provided "as is". Assurance Statement The Open Data Team checked to ensure data accuracy and consistency. Other Download dataset information: Metadata (JSON) Definitions of key terms related to this dataset can be found in the Open Data Portal Glossary: https://ukpowernetworks.opendatasoft.com/pages/glossary/ To view this data please register and login.
OpenDataSoft datasetcompatibleDistribution Future Energy Scenarios Network Scenario Headroom Report (DFES NSHR)
UpdatedOct 19, 2026Introduction UK Power Networks Network Scenario Headroom Report (NSHR) is part of the Network Development Plan (NDP). The full NDP is published every other year, and the NSHR is updated annually. The NSHR indicates the available headroom capacity in MW for demand and generation on UK Power Networks Grid and Primary substations up to 2050. It shows where reinforcement or procurement of flexibility services are needed. Since the report indicates unused substation capacity in each year, please note unused capacity may be contractually committed to customers. Those seeking connection should contact our connections gateway to understand the latest view of available capacity. The 1 May 2026 DFES NSHR dataset uses the network loading from our the Long Term Development Statement November 2025 as baseline, and our Distribution Future Energy Scenarios 2025 for the future scenarios of demand and generation. For further information on the NDP and the methodology to produce the DFES NSHR dataset please see Network Development Plan Landing Page The headroom tables are based on firm capacity. However, more capacity may be available for customers on a non-firm, flexible or curtailable connection. The demand headroom tables reflect our latest firm capacity figures for demand, consistent with the May 2025 LTDS. The generation headroom tables reflect the equipment ratings in the November 2025 LTDS. . As noted in the methodology, unused substation capacity (headroom) is indicative and may be already contractually committed to specific customers. Methodological Approach • Data Collection: Gathering data from various sources, including historical usage patterns, projected growth in renewable energy, and changes in regulatory frameworks. • Forecasting: The process begins with forecasting future network loads and demands. This often involves scenario planning to predict how energy consumption and generation will evolve to 2050. The forecast methodology is reviewed periodically to incorporate new data, stakeholder feedback, and any changes in energy policy or technology. Stakeholder inputs including local authorities Energy Plans, developers, and energy providers are considered to ensure the plans align with community needs and regulatory requirements. • Distribution Network Options Assessment Assessing the identified network constraints and developing potential solutions to address these identified constraints. This may involve traditional reinforcement methods or exploring flexibility services. • Reporting: Compiling findings into a structured report that outlines the methodology, assumptions, and planned interventions. This report is typically made available to the public for transparency. • Review and Update: The methodology is reviewed periodically to incorporate new data, stakeholder feedback, and changes in energy policy or technology. Quality Control Statement Quality Control Measures include: • Verification steps to match features only with confirmed functional locations. • Manual review and correction of data inconsistencies. • Use of additional verification steps to ensure accuracy in the methodology. Assurance Statement The Open Data Team and Network Insights Team worked together to ensure data accuracy and consistency. Other Download dataset information: Metadata (JSON) Definitions of key terms related to this dataset can be found in the Open Data Portal Glossary:https://ukpowernetworks.opendatasoft.com/pages/glossary/ If you have any questions or need clarification on any of the information shared as part of the Network Development Plan, please email our Network Insights team via [email protected] To view this data please register and login.
OpenDataSoft datasetunsupportedEarth Potential Rise (EPR) Data for Grid and Primary Sites
UpdatedNov 20, 2026Introduction The earth potential rise (EPR) dataset includes the fault current, ground return current, EPR and site classification at various voltages (132kV, 66kV, 33kV, 25kV, 20kV, 11kV, 6.6kV) for all Grid and Primary substations. This data can be used in substation earthing system design and assessment. For further information on earthing refer to UK Power Networks' earthing standard EDS 06-0001 available from our website https://g81.ukpowernetworks.co.uk/. Please send any enquiries related to the dataset to [email protected]. Methodological Approach EPR data is uploaded from UK Power Networks' data warehouse. Site Functional Locations (FLOCs) are used to associate EPR data to UK Power Networks Grid and Primary Sites Quality Control Statement Quality Control Measures include: Verification steps to match features only with confirmed functional locations. Manual review and correction of data inconsistencies. Use of additional verification steps to ensure accuracy in the methodology. Assurance Statement The Open Data Team has checked to ensure data accuracy and consistency. Other Download dataset information: Metadata (JSON) Definitions of key terms related to this dataset can be found in the Open Data Portal Glossary: https://ukpowernetworks.opendatasoft.com/pages/glossary/ To view this data please register and login.
OpenDataSoft datasetunsupportedOpen Street and Roadworks associated with UK Power Networks' activities
UpdatedNov 26, 2026Introduction To ensure we deliver a safe and reliable electricity supply or to invest in our network, we may need to carry out works on highways and footways. This dataset contains details of open street and roadworks permits and private activities taking place on the highway or on private land within the UK Power Networks footprint. See what work we are doing, where and when you can expect us to finish. This report is refreshed every two hours. For further information including contact details, please visit https://www.ukpowernetworks.co.uk/help-and-contact/roadworks-delayed-or-overrunning-works Methodological Approach Data Extraction: Data is extracted from Street Manager onto a server every two hours. Data Upload: Another script is run every two hours to upload onto an FTP server, before passing onto the Open Data Portal. Quality Control Statement Quality Control Measures include: Manual review and correction of data inconsistencies Use of additional verification steps to ensure accuracy in the methodology Please note that multiple permits can exist for one job. This may be to store equipment such as a generator. Assurance Statement The Open Data Team and Streetworks Team worked together to ensure data accuracy and consistency. Other Download dataset information: Metadata (JSON) Definitions of key terms related to this dataset can be found in the Open Data Portal Glossary: https://ukpowernetworks.opendatasoft.com/pages/glossary/
OpenDataSoft datasetunsupportedPrimary Transformer Power Flow Historic Monthly
UpdatedOct 17, 2026Introduction UK Power Network maintains the 132kV voltage level network and below. An important part of the distribution network is the stepping down of voltage as it is moved towards the household; this is achieved using transformers. Transformers have a maximum rating for the utilisation of these assets based upon protection, overcurrent, switch gear, etc. This dataset contains the Primary Substation Transformers, that typically step-down voltage from 33kV to 11kV (occasionally from 132kV to 11kV). These transformers can be viewed on the single line diagrams in our Long-Term Development Statements (LTDS) and the underlying data is then found in the LTDS tables. Care is taken to protect the private affairs of companies connected to the 11kV network, resulting in the redaction of certain transformers. Where redacted, we provide monthly statistics to continue to add value where possible. Where monthly statistics exist but half-hourly is absent, this data has been redacted. This dataset provides monthly statistics data across these named transformers from 2023 through to the previous month across our licence areas. The data are aligned with the same naming convention as the LTDS for improved interoperability. To find half-hourly current and power flow data for a transformer, use the ‘tx_id’ that can be cross referenced in the South Eastern Power Networks Primary Transformers Half Hourly Dataset or Eastern Power Networks Primary Transformers Half Hourly Dataset. If you want to download all this data, it is perhaps more convenient from our public sharepoint: Sharepoint This dataset is part of a larger endeavour to share more operational data on UK Power Networks assets. Please visit our Network Operational Data Dashboard for more operational datasets. Methodological Approach The dataset is not derived, it is the measurements from our network stored in our historian. The measurement devices are taken from current transformers attached to the cable at the circuit breaker, and power is derived combining this with the data from voltage transformers physically attached to the busbar. The historian stores datasets based on a report-by-exception process, such that a certain deviation from the present value must be reached before logging a point measurement to the historian. We extract the data following a 30-min time weighted averaging method to get half-hourly values. Where there are no measurements logged in the period, the data provided is blank; due to the report-by-exception process, it may be appropriate to forward fill this data for shorter gaps. We developed a data redactions process to protect the privacy or companies according to the Utilities Act 2000 section 105.1.b, which requires UK Power Networks to not disclose information relating to the affairs of a business. For this reason, where the demand of a private customer is derivable from our data and that data is not already public information (e.g., data provided via Elexon on the Balancing Mechanism), we redact the half-hourly time series, and provide only the monthly averages. This redaction process considers the correlation of all the data, of only corresponding periods where the customer is active, the first order difference of all the data, and the first order difference of only corresponding periods where the customer is active. Should any of these four tests have a high linear correlation, the data is deemed redacted. This process is not simply applied to only the circuit of the customer, but of the surrounding circuits that would also reveal the signal of that customer. The directionality of the data is not consistent within this dataset. Where directionality was ascertainable, we arrange the power data in the direction of the LTDS "from node" to the LTDS "to node". Measurements of current do not indicate directionality and are instead positive regardless of direction. In some circumstances, the polarity can be negative, and depends on the data commissioner's decision on what the operators in the control room might find most helpful in ensuring reliable and secure network operation. Quality Control Statement The data is provided "as is". In the design and delivery process adopted by the DSO, customer feedback and guidance is considered at each phase of the project. One of the earliest steers was that raw data was preferable. This means that we do not perform prior quality control screening to our raw network data. The result of this decision is that network rearrangements and other periods of non-intact running of the network are present throughout the dataset, which has the potential to misconstrue the true utilisation of the network, which is determined regulatorily by considering only by in-tact running arrangements. Therefore, taking the maximum or minimum of these transformers are not a reliable method of correctly ascertaining the true utilisation. This does have the intended added benefit of giving a realistic view of how the network was operated. The critical feedback was that our customers have a desire to understand what would have been the impact to them under real operational conditions. As such, this dataset offers unique insight into that. Assurance Statement Creating this dataset involved a lot of human data imputation. At UK Power Networks, we have differing software to run the network operationally (ADMS) and to plan and study the network (PowerFactory). The measurement devices are intended to primarily inform the network operators of the real time condition of the network, and importantly, the network drawings visible in the LTDS are a planning approach, which differs to the operational. To compile this dataset, we made the union between the two modes of operating manually. A team of data scientists, data engineers, and power system engineers manually identified the LTDS transformer from the single line diagram, identified the line name from LTDS Table 2a/b, then identified the same transformer in ADMS to identify the measurement data tags. This was then manually inputted to a spreadsheet. Any influential customers to that circuit were noted using ADMS and the single line diagrams. From there, a python code is used to perform the triage and compilation of the datasets. There is potential for human error during the manual data processing. These issues can include missing transformers, incorrectly labelled transformers, incorrectly identified measurement data tags, incorrectly interpreted directionality. Whilst care has been taken to minimise the risk of these issues, they may persist in the provided dataset. Any uncertain behaviour observed by using this data should be reported to allow us to correct as fast as possible. Additional information Definitions of key terms related to this dataset can be found in the Open Data Portal Glossary. Download dataset information: Metadata (JSON) We would be grateful if you find this dataset useful to submit a “reuse” case study to tell us what you did and how you used it. This enables us to drive our direction and gain better understanding for how we improve our data offering in the future. Click here for more information: Open Data Portal Reuses — UK Power Networks To view this data please register and login.
OpenDataSoft datasetcompatibleUK Power Networks Licence Area HV Poles
UpdatedSep 22, 2026Introduction A dataset showing the location of UK Power Networks' HV (High Voltage) poles. Methodological Approach Data Extraction: Shapefiles are extracted from our geospatial mapping system - NetMap. Quality Control Statement The data is provided "as is". Assurance Statement The Open Data Team checked to ensure data accuracy and consistency. Other Download dataset information: Metadata (JSON) Definitions of key terms related to this dataset can be found in the Open Data Portal Glossary: Open Data Portal Glossary To view this data please register and login.
OpenDataSoft datasetcompatibleStandard Profiles UK Power Networks Uses for Electricity Demand
UpdatedDec 3, 2024Introduction The dataset captures yearly load profiles for different demand types, used by UK Power Networks to run import curtailment assessment studies. The import curtailment assessment tool has gone live across all three licence areas in September 2024, and uses the standard demand profiles in this data publication to model accepted not-yet-connected demand customers for import curtailment studies. Demand specific profile include the following demand types: commercial, industrial, domestic, EV charging stations, bus charging depots, network rail and data centres. The profiles have been developed using actual demand data from connected sites within UK Power Networks licence areas falling into each of the demand categories. The output is a yearly profile with half hourly granularity. The values are expressed as load factors (percentages) i.e., at each half hour the value can range from 0% to 100% of the maximum import capacity. Methodological Approach This section outlines the methodology for generating annual half-hourly demand profiles. A minimum of ten connected demand sites for each of the demand types have been used to create the representative profiles. Historical data from each of these connected demand sites are either retrieved from UK Power Networks’ Remote Terminal Unit (RTU) or through smart meter data. The historical data collected consist of annual half-hourly meter readings in the last calendar year. A Python script was used to process the half-hourly MW data from each of the sites, which have been normalize by the peak MW values from the same site, for each timestamp, as follows: Pt (p.u) = P1, tPmax1 + P2, tPmax2 + … + Pn, tPmaxn where P,t(p.u) is normalised power P is the import in MW from sites 1, 2, ..., n Pmax is max import in the last calendar year, from site 1, 2, ..., n t is time, 30 minutes resolution for one year The final profile has been created by selecting a percentile ranging from 95 to 98%. Quality Control Statement The dataset is primarily built upon RTU data sourced from connected customer sites within the UK Power Networks' licence areas as well as data collected from customers smart meters. For the RTU data, UK Power Networks' Ops Telecoms team continuously monitors the performance of RTUs to ensure that the data they provide is both accurate and reliable. RTUs are equipped to store data during communication outages and transmit it once the connection is restored, minimizing the risk of data gaps. An alarm system alerts the team to any issues with RTUs, ensuring rapid response and repair to maintain data integrity. The smart meter data that is used to support certain demand profiles, such as domestic and smaller commercial profiles, is sourced from external providers. While UK Power Networks does not control the quality of this data directly, these data have been incorporated to our models with careful validation and alignment. Where MW was not available, data conversions were performed to standardize all units to MW. Any missing or bad data has been addressed though robust data cleaning methods, such as forward filling. The final profiles have been validated by ensuring that the profile aligned with expected operational patterns. Assurance Statement The dataset is generated using a script developed by the Network Access team, allowing an automated conversion from historical half hourly data to a yearly profile. The profiles will be reviewed annually to assess any changes in demand patterns and determine if updates of demand specific profiles are necessary. This process ensures that the profiles remain relevant and reflective of real-world demand dynamics over time. Other Download dataset information: Metadata (JSON) Definitions of key terms related to this dataset can be found in the Open Data Portal Glossary: https://ukpowernetworks.opendatasoft.com/pages/glossary/
OpenDataSoft datasetunsupportedUK Power Networks Licence Area LV Overhead Lines
UpdatedSep 22, 2026Introduction This dataset contains the geographical locations of Low Voltage overhead lines that are in use in the UK Power Networks licence areas. Locations are available as Geo Point (latitude and longitude) and Geo Shape. The dataset can be downloaded as a shapefile. Methodological Approach Data Extraction: Shapefiles are extracted from our geospatial mapping system - NetMap. Quality Control Statement The data is provided "as is". Assurance Statement The Open Data team has checked the data against source to ensure data accuracy and consistency. The data domain owners have checked their respective data aspects. Other Download dataset information: Metadata (JSON) Definitions of key terms related to this dataset can be found in the Open Data Portal Glossary: Open Data Portal Glossary To view this data please register and login.
OpenDataSoft datasetcompatibleUK Power Networks Primary Substation Distribution Areas
UpdatedSep 10, 2026Introduction This dataset is a geospatial view of the areas fed by primary substations. The aim is to create an indicative map showing the extent to which individual primary substations feed areas based on MPAN data. Methodological Approach Data Extraction: MPAN data is downloaded from the geographical system. The system searches with a geographical window and assigns it to the nearest supply point. Connectivity. Data is taken from the connectivity model and mapped to the relevant MPAN. Data Filtering: Any coordinates that are more than 500m from the nearest secondary site are removed. Primary Assignment: Postcodes of the MPANs are assigned to a primary substation based on the number of MPANs fed. Polygon Creation: Primary Feed Polygons are created and cleaned up to remove holes and inclusions. Hierarchy Construction: Grid Supply Point polygons are produced from schematics and merged based on hierarchical relationships. FLOC Matching: Functional Location Codes (FLOC) are matched to the respective sites. Based on the functional location (FLOC), firm capacity, season of constraint and % unutilised capacity data is taken from Long Term Development Statement (LTDS) Table 3a Observed Peak Demand Quality Control Statement Quality control measures include: Verification steps to match features only with confirmed FLOCs. Manual review and correction of data inconsistencies. Use of additional verification steps to ensure accuracy in the methodology. Regular updates and reviews documented in the version history. Assurance Statement The Open Data team, worked with the Geospatial Data Engineering team ensure data accuracy and consistency. Other Download dataset information: Metadata (JSON) Definitions of key terms related to this dataset can be found in the Open Data Portal Glossary: https://ukpowernetworks.opendatasoft.com/pages/glossary/ To view this data please register and login.
OpenDataSoft datasetcompatibleCarbon Intensity
UpdatedNov 26, 2026Introduction This beta dataset provides carbon intensity insights by Grid Supply Points (GSP) across UK Power Networks’ licence areas. It shows blended carbon intensity values for each half-hour period, helping users understand how the carbon intensity of energy varies over time and across different parts of our network. Methodological Approach Plant Information (PI) tags and values associated with generators are matched to the relevant GSP, across Eastern Power Networks (EPN) and South Eastern Power Networks (SPN), via the Embedded Capacity Register (ECR), (over 1MW only). Generator fuel types are classified using the ECR's Energy Source and Energy Conversion Technology fields, with fallback logic applied where ECR data is missing (e.g., inferring fuel type from customer name). Fuel types are then mapped to published carbon intensity factors (gCO₂/kWh) provided courtesy of NESO (National Energy System Operator). For the purposes of this beta methodology, Batteries/BESS are assigned a carbon intensity factor of 0gCO₂e/kWh. This is a simplifying assumption and may be reviewed in future iterations, as battery discharge may reflect electricity previously imported from or generated elsewhere on the system. Using the PI values, carbon intensity at the DNO (Distribution Network Operator) level (without transmission network data) is calculated using a modified equation of the original methodology provided by NESO: DCt = Σ G g=1 Eg,t × Cg Eg,t Where: DCt is the DNO-level carbon intensity, in grams of CO₂ per kilowatt hour (gCO₂e/kWh), G is total number of generators, g is the individual generator, Eg,t is the energy export of the distribution-connected generator onto the distribution network at time t in kilowatt hours (kWh) and Cg is the generator’s corresponding carbon intensity factor in gCO₂e/kWh. We divide by the sum of Eg,t because the calculation produces a GSP-level generation-weighted carbon intensity. This calculation is performed separately for each GSP and half-hour period. Each generator’s contribution is weighted according to its exported energy during the half-hour period. Transmission import/export is accounted for separately in Equation 2. Network losses and sensitivity factors are not applied in this beta methodology. PI values are recorded from the PI server in MW. Our data is half-hourly, and thus, these values are converted to kW by multiplying by 1000 and then multiplying by 0.5 for kWh. Where multiple PI readings exist within a half-hour period, the average MW value is calculated first, then converted to kWh. Super Grid Transformer (SGT) header data is then added to the dataset. The SGT active energy value represents the net energy flow at the transmission-distribution boundary: positive values indicate energy flowing from transmission into the distribution network (import), while negative values indicate energy flowing from distribution back to transmission (export). The blended carbon intensity formula extends the original NESO formula to incorporate the transmission contribution: BDCt = ((Eg,t × DCt) + (ESGT,t × Ct)) (Eg,t + ESGT,t) Where: Blended DNO carbon intensity, BDCt, at time t is calculated using the generation-weighted average carbon intensity of DNO generation, DCt, the SGT import/export energy, Esgt,t, and the NESO regional carbon intensity forecast, Ct. The SGT value represents the net energy flow at the transmission-distribution boundary during the half-hour period. Where SGT active power is recorded in kW, it is converted to kWh by multiplying by 0.5 hours. This formula is applied with the following assumptions: If sgt_energy_kwh is positive, the interval is treated as data available, and blended carbon intensity is calculated as a weighted average of local DNO generation intensity and the NESO regional carbon intensity forecast, weighted by their respective power contributions. This reflects the transmission network supplementing local generation to meet demand. If sgt_energy_kwh is negative but dno_generation_kwh + sgt_energy_kwh > 0, the interval is treated as data available, and the blended carbon intensity is set to the local weighted average carbon intensity only. The NESO forecast is disregarded because the DNO network is a net exporter - local generation exceeds demand and the surplus is flowing back to the transmission network, so no transmission network-sourced power is entering the distribution network. If sgt_energy_kwh is negative and dno_generation_kwh + sgt_energy_kwh If sgt_energy_kwh is null, the interval is treated as no data available with no transmission network data available. Without SGT data, the transmission network contribution to demand cannot be quantified and a reliable blended carbon intensity cannot be calculated. Limitations and Considerations DNO generation visibility is limited to generators registered in the ECR and matched via PI tags. Unregistered or unmetered embedded generation is not captured. The NESO regional carbon intensity forecast is used as a proxy for the carbon intensity of power imported from the transmission network. This is a regional average and may not precisely reflect the marginal generation mix at the specific GSP. Quality Control Statement Quality control measures include: Automated review to check PI tag status; and Monthly upload of new ECR Assurance Statement The Open Data Team, DSO Data Science Team, and the DSO Regional Development Team worked together to ensure data accuracy and consistency. Other Download dataset information: Metadata (JSON) Definitions of key terms related to this dataset can be found in the Open Data Portal Glossary: https://ukpowernetworks.opendatasoft.com/pages/glossary/ To view this data please register and login.
OpenDataSoft datasetcompatibleData Best Practice - Maturity Ratings
UpdatedJul 10, 2026Introduction This data shows an aggregated view of our Data Best Practice Maturity Ratings against Ofgem's Data Best Practice Principles. The details of which, can be found here: https://www.ofgem.gov.uk/decision/decision-updates-data-best-practice-guidance-and-digitalisation-strategy-and-action-plan-guidance This dataset feeds our Data Best Practice Maturity Framework page. Methodological Approach This is an aggregated snapshot of our Data Best Practice Maturity Ratings against Ofgem's Data Best Practice Principles Quality Control Statement The data is provided "as is". Assurance Statement The Open Data team has checked the data against source to ensure data accuracy and consistency. Other Download dataset information: Metadata (JSON) Definitions of key terms related to this dataset can be found in the Open Data Portal Glossary: https://ukpowernetworks.opendatasoft.com/pages/glossary/
OpenDataSoft datasetunsupportedOpen Data Portal Catalogue Metadata
UpdatedNov 26, 2026Introduction A special dataset that contains metadata for all the published datasets. Dataset profile fields conform to Dublin Core standard. Other You can download metadata for individual datasets, via the links provided in descriptions. Definitions of key terms related to this dataset can be found in the Open Data Portal Glossary: https://ukpowernetworks.opendatasoft.com/pages/glossary/
OpenDataSoft datasetunsupportedUK Power Networks Licence Area 33kV Overhead Lines
UpdatedSep 22, 2026Introduction Shapefile showing the position of UK Power Networks' 33kV overhead lines for all licence areas. Methodological Approach Data Extraction: Shapefiles are extracted from our geospatial mapping system - NetMap. Quality Control Statement The data is provided "as is". Assurance Statement The Open Data team has checked the data against source to ensure data accuracy and consistency. The data domain owners have checked their respective data aspects. Other Download dataset information: Metadata (JSON) Definitions of key terms related to this dataset can be found in the Open Data Portal Glossary: https://ukpowernetworks.opendatasoft.com/pages/glossary/ To view this data please register and login.
OpenDataSoft datasetcompatible
All endpoints loaded (131 total)