Wessex Water Wastewater Total Daily Volume Data Year to Date 2026
What is Total Daily Volume? Total Daily Volume (TDV) is the volume of effluent discharged to the environment from the permitted outfall at a Water Recycling Centre (WRC) or Wastewater Treatment Centre (WTC). Where monitoring is undertaken at a Sewage Pumping Station (SPS), TDV represents the volume of effluent passed forward to a WRC. Why is Total Daily Volume Data Collected? Wessex Water collects TDV data at sites where this monitoring is a permit requirement. The data is submitted annually to the Environment Agency (EA), who use it to assess compliance with permit conditions. How is Total Daily Volume Data Collected and Calculated? EA permits require a flow reading to be taken every 15 minutes. The majority of these measurements are collected using MCERTS-certified flow meters. These meters have been independently verified to produce TDV values within ±8% of the true daily flow. Some sites included in this dataset do not have MCERTS-certified installations (see Additional Information). The 15‑minute flow readings are used to calculate the Total Daily Volume of effluent flowing through each site using the following formula: Total Daily Volume (m3) = {Sum of ‘Good’ readings 9l/s)/ number of ‘Good’ readings} x {86,000 (S) / 1000} Quality Flags Three quality flags are automatically assigned as data enters Wessex Water’s internal database: ‘Good’, ‘Suspect’, and ‘Missing’. Data is automatically flagged as ‘Suspect’ for the following reasons: Flow readings above Qmax (the maximum flow for the monitoring installation) Flatline data (eight or more consecutive instantaneous readings identical to two decimal places) Negative flow values Data may also be manually flagged as ‘Suspect’ where there is a known issue with the flow meter that is not identified by the automatic quality assessment system. If fewer than 90% of a calendar day’s readings are flagged as ‘Good’, the TDV for that day is assigned a ‘Suspect’ flag. This flag is shown in column 5 of the dataset. If the database does not receive a flow reading for a given 15‑minute timestamp, the reading is categorised as ‘Missing’. For days with missing data, the TDV value is set to zero, even though flow is likely to have passed through the asset. Additional Information Most of the dataset is derived from wastewater assets where MCERTS‑standard monitoring is required. However, some sites without MCERTS certification are included. TDV data from these sites cannot be guaranteed to fall within ±8% of the true value, as the monitoring installations have not been subject to MCERTS verification (see Table 1 in the Appendix) When is This Data Updated? This dataset will be updated by the end of the following month. Appendix Table 1 – Sites Without MCERTS Site ID Site Name 13072 COMBE FLOREY WATER RECYCLING CENTRE 14188 LOWER STANTON ST QUINTIN SPS 17549 LOXTON WATER RECYCLING CENTRE 13188 LYDLINCH WATER RECYCLING CENTRE 17062 RINGSTEAD BAY WATER RECYCLING CENTR 17081 SANDFORD ORCAS WATER RECYCLING CENTRE 13314 TOCKENHAM WATER RECYCLING CENTRE 13514 WEST BAGBOROUGH WATER RECYCLING CENTRE Dataset Schema – Total Daily Flow Volumes Field Name DESCRIPTION DATA TYPE EXAMPLE DATA Site Name The site name of the Wessex Water wastewater asset String ABBOTSBURY WATER RECYCLING CENTRE Site ID The site identifier of the Wessex Water wastewater asset Integer 13001 Date The date the data was collected on DateTime YYYY-MM-DD Total Daily Volume The total flow recorded on this day at the specified site Float 274.6317 Units Units of flow volume String m3 Quality Flag The quality flag of the data String Good
Updated Oct 29, 2026