ARCGIS_RESTDEQOGLOklahoma, United StatesFeature Service

AirWeb - 2022 Point Source Emissions

The annual Oklahoma Point Source Emissions Inventory is a data resource that utilizes emissions data to evaluate emission trends, support air dispersion modeling, aids in development of air quality rules, and air toxics risk assessment. Summaries of annual emissions from all Oklahoma permitted facilities are available to be downloaded as excel spreadsheets. These reports are provided as a basic informational resource for the general public. Facilities registered under a Permit By Rule (PBR) are not required to report emissions inventories every year. If a facility registered under a PBR did not report in a year that they are not required to, the prior reported emission amounts are displayed in that year’s data. Column Headings Additional Notes Heading Description Company_ID The unique identifier assigned to the company by Oklahoma DEQ Company The name of the company Facility_ID The unique identifier assigned to the facility by Oklahoma DEQ Facility The name of the facility SIC The Standard Industrial Classification Code for the facility SIC codes can be found at this site https://www.sec.gov/info/edgar/siccodes.htm County The county in which the facility is located Facility_Address Physical address of the facility City City in which the facility is located State Oklahoma Zip_Code ZIP code for the facility Latitude Latitude of the facility Longitude Longitude of the facility Status The Operating Status of the facility in the year in which the emissions were reported. See right and Year_Emissions_Reported below. Not Yet Built facilities have not begun operations and have no air emissions. Operating facilities are facilities that had any regulated emissions during the year of record. Temporarily Shutdown facilities had no emissions in the year of record, but may have emissions again in the future. Permanently Shutdown facilities are closed with no emissions and would require a new permit to resume operations. SOx_Tons Tons of Sulfur Oxides emitted NOx_Tons Tons of Nitrogen Oxides emitted CO_Tons Tons of Carbon Monoxide emitted PM10_Tons Tons of PM-10 emitted. PM-10 is particulate matter with aerodynamic diameter less than or equal to 10 micrometers PM25_Tons Tons of PM-2.5 emitted. PM-2.5 is particulate matter with aerodynamic diameter less than or equal to 2.5 micrometers. PM 2.5 is a subset of PM 10 HAP_Tons Total emissions of all Hazardous Air Pollutants in tons. See right. One of the compounds on EPA's Hazardous Air Pollutants List, except those that overlap with Toxics. The list of Hazardous Air Pollutants can be found at this site https://www.epa.gov/haps/initial-list-hazardous-air-pollutants-modifications Tox_Tons Total emissions of all air Toxics in tons. See right. Any compound listed in OAC 252:100 Appendix O except those that overlap with HAPs. https://oklahoma.gov/content/dam/ok/en/deq/documents/deqmainresources/100.pdf HAP_Tox_Tons Total emissions of all pollutants that are both a HAP and an air Toxic in tons. See right. A compound that is both a HAP and is in Appendix O VOC_Total_Tons Tons of Total Volatile Organic Compounds emitted. Other_Tons Tons of emissions of Regulated Air Pollutants that do not fall into another category. Currently, this is ozone and hydrogen sulfide. See right. Regulated Air Pollutants are found in OAC 252:100 Appendix P. https://oklahoma.gov/content/dam/ok/en/deq/documents/deqmainresources/100.pdf Facility_Classification Major means a facility is a major source. Syn-Min means a facility is a synthetic minor. Min means the facility is a minor source. A facility is a major source if it has the potential to emit at least one of the following: 100 tons or more of a regulated air pollutant, 10 tons or more of a single HAP, or 25 tons or more of all HAPs. Facilities with potential emissions below major source levels will be classified as either Syn-Min or Min based on the type of permit that the facility has. Additionally, Air Curtain Incinerators, large Municipal Solid Waste Landfills, and some sources subject to National Emisions Standards for Hazardous Air Pollutants (NESHAPs) are required to obtain a major source permit even if their emissions are below major source levels (see 40 CFR 60 Subpart XXX, 40 CFR 60 Subpart CCCC, and OAC 252:100-8-3 respectively). For this reason, they are classified as Majors. A facility with a minor or synthetic minor permit will be listed as a Major if the facility's emissions are above the major source threshold in the year of record. Year_Emissions_Reported The year in which the emissions were reported. This should be 2024 for nearly all facilities. For facilities registered under a PBR, that may not have reported, the most recently reported emissions are carried forward until a new inventory is reported. Facilities registered under a PBR must submit an emissions inventory the first year that they register under the PBR then according to EPA's National Emissions Inventory schedule. The schedule for reporting for facilities registered under a PBR can be found in OAC 252:100-5-2.1. https://oklahoma.gov/content/dam/ok/en/deq/documents/deqmainresources/100.pdf

Updated Oct 15, 2026

Loading map…